How to use the NES 713 Navy Engineering Smoke Toxicity Test Chamber?

author: Views: Source: Times:2026-11-24

Summary:

The NES 713 Navy Engineering Smoke Toxicity Test Chamber is a specialized fire testing instrument designed to evaluate the toxicity of combustion products generated by materials under controlled burning conditions. In accordance with the NES 713 standard,

The NES 713 Navy Engineering Smoke Toxicity Test Chamber is a specialized piece of laboratory equipment designed to detect toxic gases generated during the combustion of materials and to determine their toxicity index. It is primarily used to evaluate the hazardous gases released when materials—such as plastics, rubber, cables, insulation, construction materials, and marine interior materials—undergo combustion. During a test, a sample of the material (of a specific mass) is placed inside a sealed test chamber and ignited by a premixed burner under defined conditions. 

Test Procedure

Before beginning the test, prepare the materials to be evaluated in accordance with the test requirements. Typical test samples include plastics, rubber, wires and cables, insulation, marine interior materials, and other flame-retardant materials. Process the materials into the dimensions and shapes required by the standard, weigh them using a precision electronic balance, and record the data. If necessary, condition the samples for temperature and humidity as stipulated by the standard to ensure consistent testing conditions. Next, verify the operational status of the test equipment. Ensure the interior of the test chamber is clean and the door is properly sealed; confirm that the burner, ignition system, temperature control system, gas-mixing fan, gas sampling system, and exhaust system are all functioning correctly. Additionally, inspect the gas supply lines and sampling lines to ensure secure connections, free from leaks or blockages. Once the equipment has been checked, start the control system according to the manufacturer’s operating instructions to complete the pre-test preparations. Place the weighed sample onto the designated sample holder inside the test chamber, positioning it within the specified combustion zone. Close the chamber, activate the burner in accordance with the combustion conditions defined by the NES 713 standard, and allow the sample to burn under the prescribed parameters. Throughout the combustion process, observe the sample’s behavior—noting its ignition, burning characteristics, melting, and total burn duration—to ensure the entire test procedure complies with the established requirements. Once the sample has finished burning, the combustion process is halted in accordance with the test procedure, and the gas-mixing fan inside the test chamber is activated to ensure the smoke and gases generated by the combustion are thoroughly mixed. This mixing process improves the uniformity of gas concentration distribution, thereby reducing measurement errors caused by uneven gas dispersion. Once the smoke and gases have reached the specified mixing conditions, they are collected from the test chamber via a dedicated sampling port and pump, and then transported to the gas detection equipment. Subsequently, the collected smoke and gases are analyzed for toxic components. In line with the requirements of the NES 713 standard, specific gas detection tubes or professional gas analyzers are used to measure the concentrations of various gases present in the combustion smoke. These typically include carbon monoxide, carbon dioxide, hydrogen chloride, hydrogen cyanide, hydrogen fluoride, hydrogen bromide, sulfur dioxide, nitrogen oxides, ammonia, hydrogen sulfide, and other gas components specified by the standard. During the detection process, appropriate analytical methods must be selected for each specific gas, and the actual measured values ​​must be recorded. For gases that may be influenced by the combustion products of the burner itself, background testing and data correction are performed as required by the standard. Following the gas concentration measurements, the results are converted into concentrations under standardized conditions, based on the sample mass, the effective volume of the test chamber, and the measured concentrations of each gas. These converted values ​​are then compared against the critical concentration thresholds defined by the NES 713 standard to calculate a toxicity factor for each gas. The sum of these toxicity factors for all specified gases yields the material's final "Toxicity Index." This index serves to evaluate the potential hazard posed by toxic gases released by a material under the prescribed combustion conditions. Generally, a lower Toxicity Index indicates that the material produces relatively lower concentrations of the relevant toxic gases under the specified test conditions. Based on these final results, testers can compare the smoke toxicity performance of different materials and determine whether a material meets the necessary usage requirements, in accordance with product technical specifications or relevant standards. Once testing is complete, the exhaust system must be activated following the equipment's operating procedures to safely vent any remaining toxic smoke and gases from the test chamber. Once it is confirmed that the internal environment is safe for opening the chamber, open the test chamber and remove any residual samples, combustion ash, or other contaminants. Inspect the burner, sample holder, gas sampling ports, and internal mixing fans for carbon deposits or contamination. Additionally, perform necessary cleaning and maintenance on the sampling lines, shut off the gas supply system and the equipment’s power, and complete the equipment usage log.

Scope of Application

In the fields of shipbuilding and marine engineering, this equipment is primarily used to test the toxicity of smoke generated by the combustion of materials such as interior finishes, bulkhead materials, flooring, ceiling materials, insulation, sealants, and marine cables. Given the relatively enclosed nature of ship interiors, a fire could lead to the accumulation of toxic smoke, posing a severe threat to the lives of crew members and passengers. Consequently, smoke toxicity testing is essential to evaluate the hazardous gases produced during material combustion, providing a basis for the selection of fire-resistant materials and the assessment of safety performance in marine applications. In the wire and cable industry, the equipment is used to detect toxic gases released during the combustion of cable insulation, sheathing materials, rubber, and other high-molecular polymers. By analyzing the concentrations of carbon monoxide, hydrogen chloride, hydrogen cyanide, and other hazardous gases, the smoke toxicity of various cable materials can be evaluated—offering critical data for material development, quality control, and the assessment of fire safety performance in cable products.

Conclusion

The NES 713 Navy Engineering Smoke Toxicity Test Chamber is designed for industries that require testing for the toxicity of smoke generated by material combustion; it is particularly well-suited for evaluating materials used in shipbuilding and marine engineering. It should be noted that NES 713 is a specific test method for smoke toxicity. When utilized in other sectors, users must verify the applicability of this method against the relevant industry standards and certification requirements. Furthermore, test results obtained via the NES 713 method should not be directly equated to compliance with other fire safety or smoke safety standards.