Ozone aging chamber
1. Equipped with a high efficiency ozone generator. It is also equipped with HMOS sensor, ozone concentration of 5ppm, control accuracy of ± 20%, with a durable ccounters. When the tank is full load for test, the ozone concentration can reach 5ppm in about five minutes;
2. Stainless steel test chamber is equipped with a large UV glass observation window, and can acheive closed-loop control of the ozone concentration.The rotating sample holder can hold up to 24 samples. The automatic shut-off featured LED lights improve the observance of the test effect;
3. In order to improve the safety performance of the device, it is equipped with door safety interlock,ozone decomposition catalyst and exhaust design with negative pressure monitoring;
4. The user can conduct on-site calibration each year, and the sensor can also be returned to the factory for calibration. Two calibration standards have NIST traceable calibration. The equipment also has periodic reminders to alert users to replace ozone decomposition catalyst and ozone generator.
How to use the ozone aging chamber?
The odor aging test box is a small amount of content, the use of medium odor conditions, the use of various odor aging methods, the use of effective anti-aging measures, and the effective use life of the odor aging test box. How do you know exactly how to use the aging test box?
1. Odor aging test test time setting
The settings are: 2 hours 30 minutes, 30 minutes, set “02” H30'', after setting the setting time, setting the adhesive cutting power "ON" switch, then setting the high temperature constant temperature operation, after the time is reached, the automatic cutting power.
2. Odor aging test box odor test test drive
Open up a green power source. The temperature of the test box reaches 40 degrees, and the temperature of the test box is set to 0. After 20 minutes, the test box temperature is set. View the table settings and use instructions.
When testing the humidity, Wuhan recommends that the water box should be heated or not, no water is added, and the temperature is set to 100%.
3. Odor aging test box activity test test.
4. Setting the odor aging test iron box warning temperature.
Maintenance
Regularly clean dirt inside and outside the test chamber, check that the door seal is tight and intact, calibrate the temperature and humidity sensors, replace filter media and moisture absorbents on schedule, ensure the drainage system is unobstructed, avoid prolonged, uninterrupted operation, and perform regular functional tests.
These maintenance measures are crucial to ensuring the proper operation of the test chamber and extending its lifespan. These routine maintenance tasks can effectively prevent equipment failures, reduce unplanned downtime, and ensure accurate and reliable test data. Furthermore, regular maintenance helps users identify potential problems early, allowing them to take preventative measures and avoid costly repairs and unnecessary production delays.